http://portal.g-node.org/odml/terminologies/v1.0/terminologies.xml
BaselineActivity-value-1 stimulus/value Modality voltage SamplingRate 100kHz StartTime 0s Duration 1e-05s Intensity 0V
FICurve-pulse-1 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.176471V IntensityOffset 0V
FICurve-pulse-2 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.0349232V IntensityOffset 0V
FICurve-pulse-3 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.442871V IntensityOffset 0V
FICurve-pulse-4 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.25629V IntensityOffset 0V
FICurve-pulse-5 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.691259V IntensityOffset 0V
FICurve-pulse-6 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.481575V IntensityOffset 0V
FICurve-pulse-7 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.932458V IntensityOffset 0V
FICurve-pulse-8 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.716975V IntensityOffset 0V
FICurve-pulse-9 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.230262V IntensityOffset 0V
FICurve-pulse-10 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.00711929V IntensityOffset 0V
FICurve-pulse-11 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.459509V IntensityOffset 0V
FICurve-pulse-12 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.248427V IntensityOffset 0V
FICurve-pulse-13 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.690563V IntensityOffset 0V
FICurve-pulse-14 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.474024V IntensityOffset 0V
FICurve-pulse-15 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.93349V IntensityOffset 0V
FICurve-pulse-16 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.719872V IntensityOffset 0V
FICurve-pulse-17 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.225135V IntensityOffset 0V
FICurve-pulse-18 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.00341825V IntensityOffset 0V
FICurve-pulse-19 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.475406V IntensityOffset 0V
FICurve-pulse-20 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.232332V IntensityOffset 0V
FICurve-pulse-21 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.711085V IntensityOffset 0V
FICurve-pulse-22 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.474375V IntensityOffset 0V
FICurve-pulse-23 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.942734V IntensityOffset 0V
FICurve-pulse-24 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.70717V IntensityOffset 0V
FICurve-pulse-25 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.23168V IntensityOffset 0V
FICurve-pulse-26 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.00393756V IntensityOffset 0V
FICurve-pulse-27 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.463534V IntensityOffset 0V
FICurve-pulse-28 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.251211V IntensityOffset 0V
FICurve-pulse-29 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.688322V IntensityOffset 0V
FICurve-pulse-30 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.489655V IntensityOffset 0V
FICurve-pulse-31 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.918563V IntensityOffset 0V
FICurve-pulse-32 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.734385V IntensityOffset 0V
FICurve-pulse-33 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.208011V IntensityOffset 0V
FICurve-pulse-34 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.0248642V IntensityOffset 0V
FICurve-pulse-35 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.440717V IntensityOffset 0V
FICurve-pulse-36 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.264077V IntensityOffset 0V
FICurve-pulse-37 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.674706V IntensityOffset 0V
FICurve-pulse-38 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.504056V IntensityOffset 0V
FICurve-pulse-39 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.906026V IntensityOffset 0V
FICurve-pulse-40 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity 0.734948V IntensityOffset 0V
FICurve-pulse-41 stimulus Modality voltage SamplingRate 1kHz
TestStimulus stimulus/pulse StartTime 0s Duration 0.4s Intensity -0.210805V IntensityOffset 0V
SAM-sine_wave-1 stimulus/sine_wave Modality voltage SamplingRate 99.5025kHz StartTime 0s Duration 1s Amplitude 1V Frequency 150.972Hz Phase 0
SAM-sine_wave-2 stimulus/sine_wave Modality voltage SamplingRate 99.5025kHz StartTime 0s Duration 1s Amplitude 1V Frequency 150.989Hz Phase 0
SAM-sine_wave-3 stimulus/sine_wave Modality voltage SamplingRate 99.5025kHz StartTime 0s Duration 1s Amplitude 1V Frequency 250.728Hz Phase 0
SAM-sine_wave-4 stimulus/sine_wave Modality voltage SamplingRate 99.0099kHz StartTime 0s Duration 1s Amplitude 1V Frequency 250.552Hz Phase 0
SAM-sine_wave-5 stimulus/sine_wave Modality voltage SamplingRate 99.5025kHz StartTime 0s Duration 0.998793s Amplitude 1V Frequency 350.423Hz Phase 0
SAM-sine_wave-6 stimulus/sine_wave Modality voltage SamplingRate 99.5025kHz StartTime 0s Duration 0.999178s Amplitude 1V Frequency 350.288Hz Phase 0
SAM-sine_wave-7 stimulus/sine_wave Modality voltage SamplingRate 99.0099kHz StartTime 0s Duration 0.999727s Amplitude 1V Frequency 450.123Hz Phase 0
SAM-sine_wave-8 stimulus/sine_wave Modality voltage SamplingRate 99.0076kHz StartTime 0s Duration 0.999923s Amplitude 1V Frequency 450.035Hz Phase 0
SAM-sine_wave-9 stimulus/sine_wave Modality voltage SamplingRate 99.0099kHz StartTime 0s Duration 1.00057s Amplitude 1V Frequency 549.686Hz Phase 0
SAM-sine_wave-10 stimulus/sine_wave Modality voltage SamplingRate 99.0099kHz StartTime 0s Duration 1.00087s Amplitude 1V Frequency 549.525Hz Phase 0
SAM-sine_wave-11 stimulus/sine_wave Modality voltage SamplingRate 99.0099kHz StartTime 0s Duration 0.999244s Amplitude 1V Frequency 749.567Hz Phase 0
SAM-sine_wave-12 stimulus/sine_wave Modality voltage SamplingRate 99.0099kHz StartTime 0s Duration 0.99882s Amplitude 1V Frequency 749.885Hz Phase 0
SAM-sine_wave-13 stimulus/sine_wave Modality voltage SamplingRate 98.5222kHz StartTime 0s Duration 0.997714s Amplitude 1V Frequency 849.943Hz Phase 0
SAM-sine_wave-14 stimulus/sine_wave Modality voltage SamplingRate 98.5222kHz StartTime 0s Duration 0.998017s Amplitude 1V Frequency 849.685Hz Phase 0
SAM-sine_wave-15 stimulus/sine_wave Modality voltage SamplingRate 99.0099kHz StartTime 0s Duration 1.00139s Amplitude 1V Frequency 949.678Hz Phase 0